Can you spur off a spur socket
WebJul 20, 2012 · 19 Jan 2010. #2. Yes you can do as you posted. I would say that lights via a non light circuit are 2nd best from a safety point of view. The risk is that someone would turn off the light circuit and not realise that some lights still remain live due to feeding off a ring circuit. They find out when there up the ladder changing a fitting ... WebWhen we pointed this out the builder ran 1 double socket on a spur to the other side of the kitchen (far too short cable left hanging loose under the cupboards but that’s another issue). There is also a bank of 4 grid switches feeding single sockets for a fridge freezer, washer, dishwasher and a cooker hood. All sockets in the kitchen (apart ...
Can you spur off a spur socket
Did you know?
WebJun 11, 2024 · Hi. First post! I have a socket on a ring which currently is occupied by a plug which operates my boiler. I would like to use this socket for something else. My idea is to spur off this (I've checked this isn't already a spur) to a 13amp FCU which my boiler would be wired into (no need for plug). Then that frees up the socket. WebIn this video I show how to wire a spur socket to a ring final circuit using 2 methods, 1. By using a junction box and connecting into the ring circuit cable...
WebMay 10, 2011 · Absolute. May 9, 2011. #2. I also believe the cooker should be a dedicated circuit. I think what you say would work, but i wouldn't do it as i don't think it's the "done thing". A socket off the outlet for a gas cooker 13a plug is acceptable, but for a non "cooker outlet" maybe not. Reply to Absolute. WebYou can connect more than one socket from a fused spur, but experts in the electrical field don’t recommend this practice due to dangerous risks. It’s recommended that only one socket comes off a fused spur to avoid overloading the cables, overheating, or even an overcurrent. The fused spur separates and isolates a branch of electricity ...
WebJan 4, 2024 · There is no need for a fused spur/fcu if you are just spurring one or two double sockets off the ring. If you take the new light from the lighting circuit, you don’t … WebNov 28, 2024 · DEACON ELECTRICAL SERVICES. You can’t spur an additional socket off of one that is a spur in the first place. You can put a fused spur unit at the origin of …
WebJan 15, 2024 · Similarly the pump will only pull 2.9A so both boiler and pump will happily coexist on the same fcu. However, from a practical point of view you would change the …
WebMar 30, 2015 · Country. 2 minutes ago. #1. I’ve seen on a few occasions that lighting circuits are fed off a fused spur running off the RFC as opposed to the lighting have a dedicated circuit with a protection device at the consumer unit. It’s also been mentioned for shed lighting in here - I think I recall from previous posts. ウチノ海公園 鳴門WebNotch the stud out to the depth of around 15mm using a chisel. Run your supply cable from the radial or ring main location, down the stud cavity, around any timbers (if any present) and then on to your new socket. … ウチノ看板WebOct 12, 2024 · Your question would be a no you can't spur a socket using a single cable, and then add a fused spur to supply more sockets. What you could do however is swap the Spurred socket for a fused spur and then add as many sockets as you like, what you are suggesting amounts to 2 spurs from the same point. Hope this helps. palazzo del pellegrino san quiricoWebThe UK is awash with spurs off spurs. I'd just put a FCU next to the first sockets and run both double sockets from that. Edit: you are allowed one spur off with a double socket because that can draw 26A (2x13A) maximum which is within the cable's 27A capacity. Ps. Slow cookers are not usually high current devices. palazzo del podesta bolognaWebMay 29, 2024 · Can I spur off an outdoor socket? You can wire an external socket in the same manner as a normal spur, by running the cable from a socket or junction box on a main ring circuit (via a switched connection unit) and mounting the socket on an external wall. Ensure your circuit has RCD protection, and that you use appropriate weatherproof … ウチノ海総合公園WebIf you are not absolutely certain, consult a professional electrician. If it has one cable, it is itself likely to be a spur and cannot, therefore, be used. If it has two cables it may be a … ウチノ海 釣り ポイントWebIt’s important to note, that according to the IEE Wiring Regulations, you are not allowed to run a spur from a socket that is already on a spur or provides power to one. It’s critical to consider the present carrying capacity of the cable and the protective device that … palazzo del popolo bucarest